220V up to 350 Degree Blackbody Furnace Calibration Infrared Calibrator

$1,350.00

SKU: 582977122330 Category:

Description

this listing is for BX350, 220V 50-350℃

infrared calibrator, blackbody furnace calibrator

BX-350

BX-500

Calibration temperature range

50-350℃

50-500℃

Basic accuracy

±0.5℃(100℃)

±0.5℃(100℃)

±1.2℃(350℃)

±1.8℃(500℃)

Stability rate

±0.1℃(100℃)

±0.1℃(100℃)

±0.2℃(350℃)

±0.3℃(500℃)

heating time

30 minutes to maximum temperature

40 minutes to maximum temperature

Cooling time

30 minutes to 100 ℃

45 minutes to 100 ℃

Resolution

0.1℃

Target diameter

57mm (2.25 inches)

Target emissivity

Fixed 0.95

power supply

AC 230v (± 10) 1.5A; or AC 110v3A

size

181 * 114 * 233mm

weight

2682g

 

BX-350 parameters:

 

【Introduction】

 

BX-350 Portable Infrared Calibrator (Blackbody Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. It has 2 types of power supply to choose from, one is AC220V and the other is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged

 

【feature】

 

Small and compact design, can calibrate infrared temperature to 350 ℃, large 2.25 inches (57mm) black body

 

     Accuracy: Ambient operating temperature is 5-35 ° C (41-95 ° F), relative humidity is 15-80%, air pressure is 75kPa-106kPa

 

± 0.5 ° C; 50 ° C <temperature≤100 ° C (± 1.2 ℉; 122 ℉ <temperature≤212 ℉)

± 1.0 ℃; 100 ℃ < temperature≤200 ℃ (± 2.0 ℉; 212 ℉ < temperature≤392 ℉)

± 1.5 ℃; 200 ℃ < temperature≤350 ℃ (± 3.0 ℉; 392 ℉ < temperature≤662 ℉)

 

     Stability: Ambient operating temperature is 5-35 ℃ (41-95 ° F), relative humidity is 15-80%, air pressure is 75kPa-106kPa

 

± 0.1 ℃; 50 ℃ <temperature≤100 ℃ (± 0.2 ℉; 122 ℉ <temperature≤212 ℉)

± 0.2 ℃; 100 ℃ < temperature≤200 ℃ (± 0.4 ℉; 212 ℉ < temperature≤392 ℉)

± 0.3 ℃; 200 ℃ < temperature≤350 ℃ (± 0.6 ℉; 392 ℉ < temperature≤662 ℉)

 

【Technical Index】

 

Range: 50 ° C-350 ° C (122 ° F-662 ° F)

Target emissivity: fixed at 0.95

Resolution: 0.1 ℃ / 0.1 ℉

Heating time: 30 minutes to the maximum temperature

Cooling time: 40 minutes to 100 ° C (122 ° F)

Target diameter: 57mm

Power supply: 220VAC (± 10%), 1.25A / 110VAC (± 10%), 2.5

Dimensions: 180 × 114 × 233mm

Weight: 3kg

 

X-500 parameters:

 

【Introduction】

 

 BX-500 Portable Infrared Calibrator (Black Body Furnace) is a hand-held, compact infrared calibrator that can perform long-distance calibration. It has two kinds of power supply to choose from, one is AC110V. Please select the correct power cord before use. If the power supply is not connected properly, the instrument will be damaged.

 

【feature】

 

1. Small and compact design,

2. Calibrate infrared high temperature to 550 ℃,

3. Hit a 2.25 inch (57mm) black body target.

 

     Accuracy

Ambient operating temperature: 5-35 ° C (41 ~ 95 ° F), relative humidity: 15 ~ 80%, air pressure: 75kPa ~ 106kPa

± 0.8 ℃; 50 ℃ <temperature≤100 ℃ (± 1.6 ℉; 122 ℉ <temperature≤212 ℉)

± 1.6 ° C; 100 ° C <temperature≤200 ° C (± 3.2 ° F; 212 ° F <temperature≤392 ° F)

± 2.8 ° C; 200 ° C <temperature≤500 ° C (± 5.6 ° F; 392 ° F <temperature≤932 ° F)

 

     stability

The ambient operating temperature is between 5 and 35 ° C (41 to 95 ° F), the relative humidity is 15 to 80%, and the air pressure is 75 kPa to 106 kPa

± 0.1 ° C; 50 ° C <temperature≤100 ° C (± 0.2 ° F; 122 ° F <temperature≤212 ° F)

± 0.2 ° C; 100 ° C <temperature≤200 ° C (± 0.4 ° F; 212 ° F <temperature≤392 ° F)

± 0.4 ° C; 200 ° C <temperature≤500 ° C (± 0.8 ° F; 392 ° F <temperature≤932 ° F)

 

【Technical Index】

 

Range: 50 ° C-500 ° C (122 ° F-932 ° F)

Target emissivity: fixed at 0.95

Resolution: 0.1 ℃ / 0.1 ℉

Heating time: 40 to maximum temperature

Cooling time: 45 minutes to 100 ° C (122 ° F)

Target diameter: 57mm

Power supply: 220VAC (± 10%), 1.25A / 110VAC (± 10%), 2.5

Dimensions: 180 × 114 × 233mm

Weight: 3kg